UL1977是用于数据、信号、控制和电力应用中使用的连接器UL认证标准,连接器UL1977认证需要进行温升测试。UL1977温升测试是测试连接器在通最大额定电流情况下部件的温度变化情况,以确定连接器工作时可被接触到的部分,是否存在温度过高造成人身伤害的风险。
UL1977温升测试产品数量
6个新样品
UL1977温升测试方法
- The temperature measurement is to be made on the wiring terminals of each device
温升测试点应布在接线端子上
- The test is to continue for 4 hours even if stabilized temperatures are attained in a shorter period of time
最少连续运行4个小时,即使温度在很短的时间内稳定
- Three consecutive readings, taken at 5 minute intervals indicate no further rise above the ambient temperature
三次连续读数,每次间隔5分钟
- All contacts are to be connected in series so as to carry the same test current.
所有的端子需要串成一个回路来通相同的电流
- Tested at a draft-free area having an ambient temperature of 25 ±5°C (77 ±9°F)
测试的环境温度应保持在25 ±5°C (77 ±9°F)
UL1977温升测试判定标准
- The measured temperature shall not exceed the Relative Thermal Index (electrical) of the insulating material
UL:最高温度不能超过塑料的RTI (Elec.) 值
UL+CUL:温升不能超过30K。
温升测试仪主要技术参数:
1、最大负载试验电压:DC5V;
2、输出恒定可调电流:DC 0.50~50.000~500.00A可调(1级);
3、数字显示,精度±(0.8%读数+0.2%量程);
4、稳定度:1%FS,反映时间小于1S;
5、工作模式:连续/通断;
6、试验时间:1~99.99h,带断电记忆功能,时间到自动降低电流停机;
7、通断工作模式:通断模式通电/断电时间:1~99.99min/小时;
8、通断次数:1~9999次,带断电记忆功能,次数到自动停机;
9、测温范围:0~260℃ 精度±0.3%读数+1℃;分辨率:0.1℃;
10、温度测量点:8路/16路/24路/48路可选配(包含1点测量环境温度);
11、测温热电偶:美国欧米伽公司T型30AWG细丝热电偶,长度3m,共8条;
12、温度数据采集:由温度数据采集仪完成,配置RS232通讯接口;
13、温度扫描速度:1~245S所有通道;
14、温度数据记录:由电脑自动完成,配置电脑测试软件;
15、软件可设置环境温度通道,采集数据时可自动减去环境温度;
16、设备电源:三相AC380V±10% 50Hz,6KVA。